Skip to main content

Table 1 Distribution of responses to survey

From: Spirometry in chronic obstructive pulmonary disease in Norwegian general practice

Question

N responses (%)

Do you request a reversibility test?

Yes

467 (74.1)

 No

160 (25.4)

 Missing

3 (0.5)

Is there significant reversibility?

 Yes

25 (4.0)

No

582 (92.4)

 Don’t know

17 (2.7)

 Missing

6 (1.0)

What is the most likely diagnosis?

 No pulmonary disorder/healthy

18 (2.9)

 Asthma

9 (1.4)

 Restrictive pulmonary disorder

26 (8.9)

COPD

512 (81.3)

 Other

10 (1.6)

 Don’t know

25 (4.0)

Which parameter(s) did you use to diagnose COPD?

 FVC

6 (1.0)

 FVC in percent of predicted

11 (1.8)

 FEV1

16 (2.5)

 FEV1 in percent of predicted

32 (5.1)

FEV1/FVC ratio

287 (45.6)

 FEV1/FVC ratio in percent of predicted

48 (7.6)

 More than one option chosen

219 (34.8)

 Missing

11 (1.8)

Which parameter(s) did you use to grade airway obstruction?

 FVC

7 (1.1)

 FVC in percent of predicted

19 (3.0)

 FEV1

113 (17.9)

FEV1 in percent of predicted

269 (42.7)

 FEV1/FVC ratio

75 (11.9)

 FEV1/FVC ratio in percent of predicted

42 (6.7)

 More than one option chosen

59 (9.4)

 Missing

46 (7.3)